The London Low Temperature Laboratory
Submitting Institution
Royal Holloway, University of LondonUnit of Assessment
PhysicsSummary Impact Type
TechnologicalResearch Subject Area(s)
Information and Computing Sciences: Artificial Intelligence and Image Processing
Engineering: Materials Engineering
Technology: Communications Technologies
Summary of the impact
The London Low Temperature Laboratory (LLTL) led by Professor Saunders in
the Department of Physics, has developed novel ultra-low temperature (ULT)
platforms and instrumentation alongside its programme of fundamental
research.
- The group's research has acted as a key driver for improvements in
scientific instrumentation, refrigeration and thermometry, which have
met critical market needs, including the capability to measure the
absolute temperature in these extreme environments.
- It has led to a direct economic impact to industry through the
development of new commercial scientific instrumentation products.
- Key partners in delivering impact are Oxford Instruments Nanoscience
(OIN), the European National Measurement Institutes (NMIs), and the
European Microkelvin Consortium.
Underpinning research
Saunders joined Royal Holloway in 1986, following the development of the
UK's first nuclear refrigeration cryostat while a PhD student at the
University of Sussex, and periods at Cornell University, and as a Royal
Society University Research Fellow. His research group has carried out
fundamental research into quantum fluids and solids at the ULT frontier,
publishing over a hundred articles in peer-reviewed journals.
The technical demands of operating in these extreme conditions have led
to the insights central to the impacts described in this case.
The production of cryogenic platforms to meet these demands was
in collaboration with an industrial partner, OIN, who turned the
proof-of-principle prototypes into commercial products. We describe
research which led to three distinct commercial products:
- The earliest example of impact resulted from a collaboration
(supported by a Royal Society Joint Project, 1988-93, and Kapitza
Fellowship, 1994) with Prof. Mikheev at Royal Holloway. The concept of
using activated charcoal as an internal pumping device in a dilution
refrigerator, removing the need for external vacuum systems was
successfully applied [1], achieving performance comparable with
conventional dilution refrigerators. Mikheev joined OIN in 1994 where
subsequent development led to the launch of a new product in 1997, the
Kelvinox AST.
- In 1997, to meet the demands for a flexible platform for ULT
experiments, compatible with the access required for using SQUID
(superconducting quantum interference device) amplifiers, a large sample
volume cryostat coupled to extensive access for wiring and services was
designed jointly by Royal Holloway/OIN and built by OIN (EPSRC Joint
Research Equipment Initiative grant [G1]) [4]. This ULT facility became
the prototype of the high-access OIN Kelvinox 400HA cryostat, launched
as a commercial product in 1998. The suitability of the facility for
SQUID based experiments was demonstrated through the programme of work
carried out in [G4].
- The advent of cryogen-free dilution refrigerators, a rapidly growing
sector of turn-key low temperature platforms, has been of central
importance to the field of new quantum technologies. Within the European
Microkelvin consortium [G7] the LLTL has been promoting access to ULT
for the nanoscience community. A Royal Holloway/OIN collaboration was
the first to successfully combine nuclear demagnetisation with
cryogen-free operation to reach sub-mK temperatures [6], launched
commercially in July 2013.
A related strand of research, of crucial relevance to ULT research and
its technological applications concerns thermometry. This has
involved partnerships with OIN and with NMIs. An unsolved problem of
crucial relevance in low temperature physics was the ability to accurately
and conveniently measure the temperature, using a method traceable to
international temperature scales. The Royal Holloway group were the first
to demonstrate, on the ULT facility described previously, the practicality
of a current-sensing noise thermometer (CSNT) [2,3] for operation from 4 K
down to below 1 mK [patent P1]. The method exploits DC SQUIDs to detect
Nyquist thermal noise in a sensor. The direct link to the Boltzmann
constant, kB, is of particular relevance to the
NMIs, with whom we collaborate [4,5] in the dissemination of the
Provisional Low Temperature Scale (PLTS-2000). Through the European
Metrology Research Programme [G8] we are working to establish a new scale
to resolve discrepancies within PLTS-2000. Following [2,3] we have
developed an improved simple, practical and fast device, which measures
temperature with 1% precision in less than a second. The technology is
licensed to OIN, leading to the phasing out of the use of the Cobalt-60
Nuclear Orientation thermometer, to field test their cryostats. This
thermometer relies on its natural radioactivity, resulting in extensive
regulation for handling and transport, is slow and useful over only a
limited temperature range.
The step-change in performance arising from the advances made through our
research are transforming thermometry in this temperature range, by
providing a thermometer which can cover the entire temperature range, from
4K into the microkelvin regime, with high precision, and without the need
for calibration.
References to the research
Selected Peer-Reviewed Papers, author at RHUL; * denotes papers
that best indicate quality.
1) 1994 Continuously operating cryogenic cycle dilution
refrigerator P. Mohandas, B.P. Cowan, J. Saunders, V.K.
Chagovets, V.N. Lukashov, V.A. Maidanov, N.P. Mikhin, N.F.
Omelaenko, E.Ya. Rudavskii and V.A. Mikheev, Physica B: Condensed
Matter, Volumes 194-196, Part 1, 55-56 (1994).
2) *2001 Current sensing noise thermometry using a low Tc
DC SQUID preamplifier. C.P. Lusher, J. Li, V.A Maidanov, M.E.
Digby, H. Dyball, A. Casey, J Nyéki, V.V. Dmitriev, B.P. Cowan,
J. Saunders, Measurement Science & Technology, Vol. 12, No. 1,
115 (2001). Awarded best paper in Measurement Science and
Technology 2001.
3) 2003 Current-sensing noise thermometry from 4.2 K to below
1 mK using a DC SQUID preamplifier. A. Casey, B.P. Cowan, H.
Dyball, J. Li, C.P. Lusher, V. Maidanov, J. Nyéki, J. Saunders, D.
Shvarts, Physica B, Vol. 329, 1556-1559 (2003).
4) 2003 Nuclear magnetic resonance using DC SQUIDs with APF
A. Casey, B. Cowan, M. Digby, H. Dyball, R. Körber, J. Li, C. Lusher,
V. Maidanov, J. Nyéki, J. Saunders, D. Drung, T. Schurig, Physica C:
Superconductivity, Vol. 399, 93-97 (2003).
5) *2003 European Dissemination of the ultra-low temperature
scale, PLTS-2000, R Rusby, D Head, D Cousins, H Godfrin, YM Bunkov,
R Rapp, F Gay, M Meschke, CP Lusher, J Li, A Casey, D Shvarts, BP
Cowan, J Saunders, V Mikheev, J Pekola, K Gloos, P Hernandez, S
Triqueneaux, M Groot, A Peruzzi, R Jochemsen, A Chinchure, E van Heumen,
GE de Groot, W Bosch, F Mathu, J Flokstra, D Veldhuis, Y Hermier, L Pitre,
A Verge, B Fellmuth, J Engert. Temperature: Its Measurement and Control in
Science and Industry: AIP Conference Proceedings Vol. 684, 89-94 (2003).
6) *2013 A microkelvin cryogen-free experimental platform
with integrated noise thermometry G Batey, A Casey, M
Cuthbert, A Matthews, J Saunders, A Shibahara, arXiv:1307.7049v1,
to be published in New Journal of Physics.
Key Grants, referred to in text as [G#]
1) EPSRC Joint Research Equipment Initiative: Ultra-low temperature
facility for application of SQUID technology to noise thermometry and
NMR (1997-98) EPSRC GR/L24465/01; £62,247 with matching funds from
industrial partner (Oxford Instruments). PI J. Saunders.
2) Royal Society Joint Project with PTB Berlin: Application of SQUIDs
to Nuclear Magnetic Resonance and Noise Thermometry (April 1999-
March 2001); £7,600.
3) Royal Society Study Visit from Russia for Dr V Maidanov (Jan - April
2000) £4,325.
4) EPSRC Instrument Development Call: NMR Instrumentation using DC
SQUIDs for experiments at ultra-low temperatures and on room temperature
samples (May 1999- April 2003) EPSRC GR/M51291; £545,597. J.
Saunders, C.P. Lusher and B.P. Cowan. (Final report ranking:
outstanding).
5) Dissemination of the European Ultra-Low Temperature Scale
(Jan. 2000 - Dec. 2002) EU Framework V, 12 Partners, Contract
G6RD-CT-1999-00119; €150,000 to Royal Holloway.
6) West Focus Project for Accessible Research Knowledge (PARK) Fund: Ultra-Low
Temperature
Thermometry (2009); £40,680. PI A. Casey.
7) European Commission FP7: European Microkelvin Collaboration
(April 2009 - Sep 2013) grant no. 228464, Capacities Specific Programme,
Research Infrastructures; €288,000 Royal Holloway share. J. Saunders (PI),
P.J. Meeson.
8) European Metrology Research Programme (EMRP): Implementing the new
Kelvin (June 2012 - 2015) grant JRP-s13 InK. Researcher Excellence
Grant (Researcher Dr Aya Shibahara); €287,000.
9) Application of SQUID NMR to the study of novel p-wave 3He
superfluids in regular confined geometries (April 2005 - March 2008)
EPSRC EP/C522877/1; £518,606. J. Saunders (PI), B.P. Cowan, C.P. Lusher,
A. Casey; (underpinning grant).
Patents, referred to in text as [P#]
1) US Patent No. 6357912: Current Sensing Noise Thermometer 2002 (Royal
Holloway, University of London and J. Li)
Details of the impact
The primary beneficiary of our impact is OIN, and through them to a wider
community of scientists and industrial facilities that require ULT
platforms and reliable, convenient thermometry. The CSNT has also had
direct impact on the NMIs that maintain and disseminate the temperature
scales.
A strong program of collaboration and joint development with Oxford
Instruments Nanoscience, has led to the creation of new innovative
products. OIN is a global company that creates high performance
cryogenic and cryogen-free environments for ultra-low temperature and high
magnetic field applications in physics, chemistry and materials science.
The importance of these products has been recognised through a Queens
Award to Industry 2010, and the IoP Gold Medal in Business and
Innovation (Dr Graham Batey, 2011). These products have contributed
to OIN maintaining its leading world market share. The Technical Director
of OIN states in a letter of support: "By identifying key areas of
collaboration and joint development it is clear that RHUL and OIN have
been able to use a strong and fruitful partnership for the benefit of
the wider scientific community by developing new products, the UK
economy by providing employment and commerce and the local scientific
community by providing training, collaboration and career development."
This partnership was formalised through a 2010 Memorandum of Understanding
(MoU) between Royal Holloway and OIN. OIN has invested in Royal Holloway
through a £200k contribution to a £800k low temperature infrastructure
upgrade in 2010. This consisted of a new nuclear demagnetisation cryostat
for the study of semi-conductor samples at ULT and a cryogen-free dilution
refrigerator which provided the platform for the first demonstration of
nuclear cooling below 1 mK on a cryogen-free system. This activity is
supported by a matched funding Impact PhD studentship.
The impact of the specific products developed is:
(1) The 1994 development of the cryogenic cycling fridge led directly to
the 1997 product launch of the Kelvinox AST. OIN built and delivered over
15 such systems up until 2003, with a combined revenue of £1.3M. Most of
these systems are still in use today.
(2) The Kelvinox 400HA was developed based upon the prototype produced
through the EPSRC Joint Research Equipment Initiative [G1]. This product
has been on sale since 1998 and plays an active part in OIN's current
portfolio with over 50 systems delivered, with a combined revenue of over
£7M.
(3) Based on the prototype microkelvin cryogen-free experimental
platform, OIN have launched in July 2013 the first such product,
responding to demand from the Quantum Information Processing community.
OIN are projecting that this field will develop into a global market worth
$1B by 2025.
Practical primary thermometry for ULT applications. The impact of
the development of the Current Sensing Noise Thermometer comes through its
influence on the policies of NMIs such as PTB (Berlin) and NPL (London)
and changing the procedures of OIN.
Disseminating the PLTS-2000 scale, where noise thermometry plays a
critical role, was achieved through the FP5 funded programme [G5]
supported by a Royal Society Study visit [G3]. This emphasized
discrepancies in PLTS-2000 [4,5], which are being addressed by the
EMRP-funded programme JRP-s13 "Implementing the new Kelvin" [G8]. This
EMRP project will arrive at a better determination of thermodynamic
temperature.
Through the EMRP project and building on earlier research [2,3], and
subsequent development partly funded by the West Focus PARK Fund [G6], in
2009 we developed a practical, fast and user friendly noise thermometer.
This provides a practical route for disseminating thermodynamic
temperatures to end users. The impact is to enable industrial suppliers of
low temperature platforms to factory test the performance, to test on site
as part of commissioning, and importantly to allow users/customers
themselves to confirm continued operation. Our set-up was successfully
tested on the OIN factory site at Tubney Woods, and future OIN
cryogen-free systems will be delivered with a current sensing noise
thermometer for onsite performance tests, replacing the Cobalt-60
thermometer currently used.
Via our collaboration with PTB [G2, G7 and G9] our work has stimulated
the production of a related noise thermometer by Magnicon GmbH, a spin-off
company of PTB. Their product, the MFFT-1 (magnetic field fluctuation
thermometer), was launched in 2008 at ULT2008, "Frontiers of Low
Temperature Physics", a conference organised at Royal Holloway.
The long standing relationship with OIN has also helped supply their need
for high quality postgraduate level staff. Royal Holloway students and
staff who went on to work for Oxford Instruments: Marcio Siqueira,
formerly of OIN, founder of Almax easyLab; Vladimir Mikheev, until
recently a consultant engineer at OIN involved in development of
cryogen-free dilution refrigerators; Simon Kingsley, now ULT
engineer at OIN; Junyun Li of OIN China; Hetal Patel,
development engineer at OI Molecular Biotools.
Sources to corroborate the impact
The work on the development and impact of OIN products can be confirmed
by the Technical Director of OIN and, specifically for the Kelvinox 400HA,
the OIN Consultant Engineer who collaborated on the project.
The influence on NMIs and temperature scales can be confirmed by the Head
of Temperature Standards, National Physical Laboratory, (who is the
coordinator of the EMRP project "Implementing the new Kelvin") and
the Director, Cryophysics and Spectrometry, Physikalisch-Technische
Bundesanstalt Institut, EMRP project partner and European Microkelvin
Consortium partner.
Supporting documents:
- MoU between Royal Holloway and Oxford Instruments, for collaborative
research projects (2010), and current-sensing noise thermometry
licensing agreement (2013);
- http://www.oxford-instruments.com/news/2013/october/new-groundbreaking-cryogen-free-micro-kelvin-refri
- Strategic Partnership Agreement between Royal Holloway and NPL, signed
September 2011;
- Report to the European Commission: Development and Evaluation of the
Current Sensing Noise Thermometer (June 2004);
- Final report, European Microkelvin Consortium (September 2013).